     Cell Adhesion Flow Chamber

pix.GIF (45 bytes)
pix.GIF (45 bytes)pix.GIF (45 bytes)pix.GIF (45 bytes)

pix.GIF (45 bytes)

Description
of Use

pix.GIF (45 bytes)

The Immunetics Cell Adhesion Flow Chamber is designed for performing dynamic cell adhesion assays in a laminar flow environment. The transparent acrylic device permits the study of interactions between cells immobilized on a microscope slide and cells in the fluid phase. Immobilized cells are grown on a detachable slide culture vessel. The Flow Chamber is mounted on an inverted microscope, cells in suspension are pumped through the chamber and cell-cell interactions are monitored in real time by video microscopy. The design solves several problems, including establishment of true laminar flow without turbulence, and leak-proof, reversible sealing of the culture slide to the chamber by vacuum. Applications for the Flow Chamber include studies of cell adhesion and cell-cell interactions in immunology and cell biology.
pix.GIF (45 bytes)

pix.GIF (45 bytes)pix.GIF (45 bytes)pix.GIF (45 bytes)

pix.GIF (45 bytes)

Technical Specifications

pix.GIF (45 bytes) Accepts any microscope slide - cell culture vessel
  • Depth of flow deck = 250 µ, volume = 50 µl
  • Shear stress range 0.3 - 1.8 dyne/cm2
  • Compatible with syringe pumps for controlling liquid flow
  • Mounts on a microscope stage equipped to manipulate 96-well plates
pix.GIF (45 bytes)pix.GIF (45 bytes)pix.GIF (45 bytes)

pix.GIF (45 bytes)

Unique Features pix.GIF (45 bytes)
  • Rapid stability of laminar flow with minimal turbulence
  • Leak-proof vacuum sealing between slide and chamber
    pix.GIF (45 bytes)
pix.GIF (45 bytes)pix.GIF (45 bytes)pix.GIF (45 bytes)

pix.GIF (45 bytes)

pix.GIF (45 bytes)Schematic of the Flow Chamber showing top and side views. Vacuum is applied between the two O-ring gaskets to anchor the slide, and is isolated from the flow deck by the gaskets. Cells in fluid phase are introduced via inlet and outlet ports. A series of five apertures in inlet and outlet manifolds facilitates rapid stabilization of laminar flow. External vacuum maintains a constant gap between the culture slide (crosshatched) and the flow deck. All liquid and vacuum fittings accept luer connectors. (See diagram below)

ordering information: catalog # CAF10



Immunetics, Inc.
27 Drydock Ave, 6th Floor, Boston MA 02210 USA
Tel: 617.896.9100    Toll-Free: 800.227.4765
Fax: 617.896.9110    email: info@immunetics.com

© Copyright 1997 Immunetics, Inc. All Rights Reserved.
Miniblot, Miniblotter and Immunetics are registered trademarks, and MiniSlot, and QualiCode, are trademarks of Immunetics, Inc.